Teilenummer
Hier finden Sie die Teilenummern
zu dem gesuchten Artikel
NJW-16-RCA
Model | Shell Size | Type | Weight (g) |
NJW | 16 | PCA For Straight | 18 |
20 | 20 | ||
24 | 22 | ||
28 | 13 | ||
16 | RCA For Panel Mounting | 10 | |
20 | 11 | ||
24 | 13 | ||
28 | 9 | ||
16 | ADCA For Relay | 11 | |
20 | 13 | ||
24 | 14 | ||
28 | 11 |
Teilenummer
|
---|
NJW-16-RCA |
Teilenummer |
Standard-Stückpreis
| Mindestbestellmenge | Mengenrabatt | Specifications | Compatible Shell Size | |
---|---|---|---|---|---|---|
9.61 € | 1 | 6 Arbeitstage | For Panel Mounting | 16 |
Loading...
Waterproof Medium Type Connectors (NJW)
Features
● NJW series connectors are round metal connectors, designed to enhance water-proofing functionality when mated. (IPX7 equivalent)Common Specifications
Materials / Finish
Item | Materials | Finish |
---|---|---|
Shell / Dustproof Cap | Zinc or Aluminum Alloy (shell size 28) |
Chrome Plated or special chemical processing |
Insulator | Synthetic Resin | - |
Contact | Copper Alloy | Silver Plating |
Rubber Packing | Synthetic Rubber | - |
Characteristics
Item | Contents |
---|---|
Rated Current | Check with the table below. |
Rated Voltage | Check with the table below. |
Withstand Voltage | No abnormality such as short circuiting occurs when regulated voltage is applied for 1 minute between immediately adjacent conductors. |
Insulation Resistance | 1,000 MΩ or higher when measured between immediately adjacent conductors with regulated voltage. |
Contact Resistance | Conductor resistance is 5 mΩ or less when a pair of contacts are connected at up to the regulation length. |
Vibration Resistance | No functional defect was found during the JIS C 5025 vibration test. Contact resistance is 5 mΩ or less. |
Impact Resistance | No functional defect was found during the JIS C 5026 shock test. Contact resistance is 5 mΩ or less. |
Repeated Operation | No functional defect was found when a removal and insertion sequence was tested 500 times. Contact resistance is 5 mΩ or less. |
Humidity Resistance | No functional defect was found during the JIS C 5023 humidity test. Insulation resistance is 100 MΩ. |
Temperature Cycle | No functional defect was found during the JIS C 5030 temperature cycle test. |
Corrosion Resistance | No functional defect was found during the JIS C 5028 salt water spray test. Contact resistance is 5 mΩ or less. |
Waterproofing | No abnormality such as flooding was found when left under water pressure of 0.4 kgf/cm2 at regular working conditions for 24 hours or more. |
Operating Temperature Range | -25°C ~ +85°C |
Table of Basic Specifications
Product No. | Shell Size |
Number of Cores | Shape Symbol | Rated Current (A or less) |
Rated Voltage (V or less) |
Withstand Voltage AC (V) |
Insulation Resistance (MΩ or higher) |
Contact Resistance (mΩ or less) |
Compatible Wire Size | Applicable Electric Wire Finished Outer Diameter (mm) Note 1 |
|
---|---|---|---|---|---|---|---|---|---|---|---|
AWG | Conductor Section Area mm2 | ||||||||||
NJW | 16 | 3 | PF, RM, ADM |
10 | 125 | 1,500 | 2,000 | 3 | 16 | 1.25 | 8.0 ~ 11.0 |
5 | 5 | 1,000 | 1,000 | 5 | 20 | 0.5 | |||||
16 | 3 | PM, RF, ADF |
10 | 125 | 1,500 | 2,000 | 3 | 16 | 1.25 | 8.0 ~ 11.0 | |
5 | 5 | 1,000 | 1,000 | 5 | 20 | 0.5 | |||||
20 | 2, 3 | PF, RM, ADM |
15 | 250 | 1,500 | 2,000 | 3 | 14 | 2 | 7.0 ~ 12.5 | |
4, 5 | 10 | 16 | 1.25 | ||||||||
7 | 1,000 | ||||||||||
12 | 5 | 1,000 | 5 | 20 | 0.5 | ||||||
20 | 2, 3 | PM, RF, ADF |
15 | 250 | 1,500 | 2,000 | 3 | 14 | 2 | 7.0 ~ 12.5 | |
4, 5 | 10 | 16 | 1.25 | ||||||||
7 | 1,000 | ||||||||||
12 | 5 | 1,000 | 5 | 20 | 0.5 | ||||||
24 | 2, 3 | PF, RM, ADM |
20 | 250 | 1,500 | 5,000 | 3 | 12 | 3.5 | 9.5 ~ 15.0 | |
4, 5 | 15 | 14 | 2 | ||||||||
10 | 10 | 1,000 | 2,000 | 16 | 1.25 | ||||||
14, 16 | 5 | 1,000 | 5 | 20 | 0.5 | ||||||
24 | 2, 3 | PM, RF, ADF |
20 | 250 | 1,500 | 5,000 | 3 | 12 | 3.5 | 9.5 ~ 15.0 | |
4, 5 | 15 | 14 | 2 | ||||||||
10 | 10 | 1,000 | 2,000 | 16 | 1.25 | ||||||
14, 16 | 5 | 1,000 | 5 | 20 | 0.5 | ||||||
28 | 16 | PF, RM, ADM |
10 | 250 | 1,000 | 2,000 | 3 | 16 | 1.25 | 12.5 ~ 18.0 | |
24 | 5 | 1,000 | 5 | 20 | 0.5 | ||||||
28 | 16 | PM, RF, ADF |
10 | 250 | 1,000 | 2,000 | 3 | 16 | 1.25 | 12.5 ~ 18.0 | |
24 | 5 | 1,000 | 5 | 20 | 0.5 |
Contact Arrangement Diagram
Connection Work Method
Sie befinden sich auf der Seite für NJW Waterproof Cap, die Teilenummer ist NJW-16-RCA.
Sie finden detaillierte Informationen über Spezifikation und Dimensionierung unter der Teilenummer NJW-16-RCA.
Konfigurieren
Basiseigenschaften
Specifications
Compatible Shell Size
Filtern nach CAD Format
Filtern nach vsl. Lieferzeit
Optionale Eigenschaften
Teilenummer |
---|
NJW-16-ADCA |
NJW-16-PCA |
NJW-20-ADCA |
NJW-20-PCA |
NJW-20-RCA |
NJW-24-ADCA |
Teilenummer | Standard-Stückpreis | Mindestbestellmenge | Mengenrabatt | Reguläre Versanddauer ? | Specifications | Compatible Shell Size |
---|---|---|---|---|---|---|
10.30 € | 1 | Verfügbar | 5 Arbeitstage | For Relay | 16 | |
19.26 € | 1 | Verfügbar | 5 Arbeitstage | For Straight | 16 | |
10.81 € | 1 | Verfügbar | 6 Arbeitstage | For Relay | 20 | |
20.07 € | 1 | Verfügbar | 5 Arbeitstage | For Straight | 20 | |
10.35 € | 1 | Verfügbar | 5 Arbeitstage | For Panel Mounting | 20 | |
14.32 € | 1 | Verfügbar | 5 Arbeitstage | For Relay | 24 |