Produktdetails:

Hersteller-Teilenummer: NRW-20-PCA-1

Marke: MISUMI

Preis: 5.00

Lieferzeit: 5 Arbeitstage


Technische Daten:

Specifications: For Straight

Compatible Shell Size: 20



● Prevents intrusion of dust and foreign matter when not connected.
● Three models: for straight, for relay, and for panel mounting.

Teilenummer

Hier finden Sie die Teilenummern
zu dem gesuchten Artikel

NRW-20-PCA-1

Spezifikationen

NRW Waterproof Cap:Related Image

ModelShell SizeShape SymbolWeight
(g)
NRW20PCA-1
For Straight
5
246
2810
20RCA-1
For Panel Mounting
10
2414
2821
20ADCA-1
For Relay
12
2414
2821

Weitere Informationen

NRW Waterproof Cap:Related Image
Teilenummer
NRW-20-PCA-1
Teilenummer
Standard-Stückpreis
MindestbestellmengeMengenrabatt
Reguläre
Versanddauer
?
RoHSSpecifications Compatible Shell Size

5.00 €

1 Verfügbar 5 Arbeitstage 10For Straight20

Loading...

  1. 1

Features

● NRW series connectors are round connectors, designed to enhance water-proofing functionality when connected. (IP67 equivalent)
● Superior weather and impact resistance due to the high-strength plastic material used.
● NRW series products are suitable for power supplies.
● There are 3 types of connectors: Straight, relay, and panel mount connectors.
● Because these connectors are connected by soldering, no dedicated tool is required for wiring.

Materials / Finish

Item Materials Finish
Shell Synthetic Resin -
Insulator Synthetic Resin -
Contact Copper Alloy Silver Plated
Packing Synthetic Rubber -

Connector Diagram

Characteristics

Item Contents
Rated Current Check with the table below.
Rated Voltage Check with the table below.
Withstand Voltage No abnormality such as short circuiting occurs when regulated voltage is applied for 1 minute between immediately adjacent conductors.
Insulation Resistance 1,000 MΩ or higher when measured between immediately adjacent conductors with regulated voltage.
Contact Resistance Conductor resistance is 5 mΩ or less when a pair of contacts are connected at up to the regulation length.
Vibration Resistance No functional defect was found during the JIS C 5025 vibration test. Contact resistance is 5 mΩ or less.
Impact Resistance No functional defect was found during the JIS C 5026 shock test. Contact resistance is 5 mΩ or less.
Repeated Operation No functional defect was found when a removal and insertion sequence was tested 500 times. Contact resistance is 5 mΩ or less.
Humidity Resistance No functional defect was found during the JIS C 5023 humidity test. Insulation resistance is 100 MΩ.
Temperature Cycle No functional defect was found during the JIS C 5030 temperature cycle test.
Corrosion Resistance No functional defect was found during the JIS C 5028 salt water spray test. Contact resistance is 5 mΩ or less.
Waterproofing No abnormality such as flooding was found when left under water pressure of 0.4 kgf/cm2 at regular working conditions for 24 hours or more.
Operating Temperature Range -25°C ~ +85°C

Table of Basic Specifications

Product No. Shell
Size
Number of Cores Shape Symbol Rated Current
(A or less)
Rated Voltage
(V or less)
Withstand Voltage
AC (V)
Insulation Resistance
(MΩ or higher)
Contact Resistance
(mΩ or less)
Compatible Wire Size Applicable Electric Wire
Finished Outer Diameter (mm) Note 1
AWG Conductor Section Area mm2
NRW 20 2, 3 PF, RM,
ADM
15 250 1,500 2,000 3 14 2 7.0 ~ 12.5
4, 5 10 16 1.25
7 1,000
12 5 1,000 5 20 0.5
20 2, 3 PM, RF,
ADF
15 250 1,500 2,000 3 14 2 7.0 ~ 12.5
4, 5 10 16 1.25
7 1,000
12 5 1,000 5 20 0.5
24 2, 3 PF, RM,
ADM
20 250 1,500 5,000 3 12 3.5 9.5 ~ 15.0
4, 5 15 14 2
10 10 1,000 2,000 16 1.25
14, 16 5 1,000 5 20 0.5
24 2, 3 PM, RF,
ADF
20 250 1,500 5,000 3 12 3.5 9.5 ~ 15.0
4, 5 15 14 2
10 10 1,000 2,000 16 1.25
14, 16 5 1,000 5 20 0.5
28 16 PF, RM,
ADM
10 250 1,000 2,000 3 16 1.25 12.5 ~ 18.0
24 5 1,000 5 20 0.5
28 16 PM, RF,
ADF
10 250 1,000 2,000 3 16 1.25 12.5 ~ 18.0
24 5 1,000 5 20 0.5

Note 1: Even connectors with the same shell sizes may be divided into 2 or 3 types depending on the thickness of the cable used. Take care at selection. Refer to each product page for further details.

Contact Arrangement Diagram

Contact Arrangement Diagram

Connection Work Method

Connection Work Method
Connection Work Method

Sie befinden sich auf der Seite für NRW Waterproof Cap, die Teilenummer ist NRW-20-PCA-1.
Sie finden detaillierte Informationen über Spezifikation und Dimensionierung unter der Teilenummer NRW-20-PCA-1.

Produktvarianten

Teilenummer
NRW-20-ADCA-1
NRW-20-RCA-1
NRW-24-ADCA-1
NRW-24-PCA-1
NRW-24-RCA-1
NRW-28-ADCA-1
TeilenummerStandard-StückpreisMindestbestellmengeMengenrabattReguläre
Versanddauer
?
RoHSSpecifications Compatible Shell Size

12.68 €

1 5 Arbeitstage 10For Relay20

12.66 €

1 Verfügbar 5 Arbeitstage 10For Panel Mounting20

14.85 €

1 Verfügbar 5 Arbeitstage 10For Relay24

9.42 €

1 5 Arbeitstage 10For Straight24

15.67 €

1 5 Arbeitstage 10For Panel Mounting24

18.19 €

1 6 Arbeitstage 10For Relay28

Technischer Support