IRV10 / 20, Vakuumregler (Teilenummern - CAD Download)

IRV10 / 20, Vakuumregler

Klicken Sie auf dieses Bild, um es zu vergrößern.

Klicken Sie auf dieses Bild, um es zu vergrößern.

A vacuum regulator capable of controlling the pressure of the vacuum line.
[Features]
· Can control the pressure of the vacuum line
· Single-sided connection series.
· Weight reduced by 20% (compared to conventional models).
· One-tough fittings.
· Clip attachment type that makes is easy to attach/detach the pressure gauge or digital pressure switch.
· Mounting direction of the pressure gauge or digital pressure switch can be changed (only in standard connections).
· The mounting angles of the pressure gauge or digital pressure switch can be changed easily (in 60° increments).

(i)Hinweis

  • Bei den Produktbildern handelt es sich möglicherweise nur um repräsentative Bilder. Einzelheiten zur Form entnehmen Sie bitte dem Katalog des Herstellers.

Teilenummer

Hier finden Sie die Teilenummern
zu dem gesuchten Artikel

Vacuum Regulator IRV10/20 Series Specifications

ModelIRV10IRV20
Usable fluidsAir
Set pressure rangeNote 1)-100 to -1.3 kPa
Withstand pressureNote 2)100 kPa (except with pressure gauge)
Atmospheric intake consumptionNote 3)0.6 L/min (ANR) or less
Knob resolution0.13 kPa or less
Ambient and fluid temperature5 to 60°C
VAC side tubing outer diameterø6 (diameter 6 mm), ø8 (diameter 8 mm)
ø1/4" (diameter 1/4" mm), ø5/16" (diameter 5/16" mm)
ø6 (diameter 6 mm), ø8 (diameter 8 mm), ø10 (diameter 10 mm)
ø1/4" (diameter 1/4" mm), ø5/16" (diameter 5/16" mm), ø3/8" (diameter 3/8" mm)
SET side tubing outer diameter
Weight (without accessories)Standard connections135 g (IRV10-C08)250 g (IRV20-C10)
Single-sided connections125 g (IRV10A-C08)250 g (IRV20A-C10)

Note 1) Varies depending on the pressure of the vacuum pump.
Note 2) Supplying positive pressure to vacuum regulators equipped with a pressure gauge may damage the pressure gauge. Application of positive pressure will not damage the vacuum regulator; however, the main valve will open and positive pressure will enter the vacuum pump, which may cause malfunction of the vacuum pump. When using the vacuum regulator in a suction transport system, etc., refer to the following piping example so as to avoid supplying positive pressure to the vacuum pump. This vacuum regulator is not capable of adjusting positive pressure.
Note 3) Constantly intakes the atmospheric air.

Structural Diagram

Structural Diagram

Structural Diagram

Working Principle

When the knob is turned to the right (clockwise), the adjusting spring’s generated force pushes down the diaphragm and the valve. This connects the VAC side and SET side, and the degree of vacuum on the SET side increases (becomes closer to an absolute vacuum).
Furthermore, the SET side vacuum pressure moves through the air passage into the vacuum chamber, where it is applied to the top side of the diaphragm and counters the adjusting spring’s compression force; and this adjusts the SET side pressure. When the degree of vacuum on the SET side is higher than the designated setting value (becomes closer to an absolute vacuum), the balance between the adjusting spring and the SET side pressure in the vacuum chamber is lost, and the diaphragm is pushed up. This causes the valve to close and the atmospheric intake valve to open, which lets atmospheric air into the SET side. When the adjusting spring’s compression force and the SET side pressure are balanced, the SET side pressure is set. Also, when the degree of vacuum of the SET side pressure is lower than the designated setting value (becomes closer to the atmosphere), the balance between the adjusting spring and the vacuum chamber is lost, and the diaphragm is pushed down.
This causes the atmospheric intake valve to close and the valve to open, which lets air into the VAC side. When the adjusting spring's compression force and the SET side pressure are balanced, the SET side pressure is set.

Drawing of IRV10: Standard Connection

 

(Unit: mm)

 

IRV10: Standard Connections Drawing

IRV10: Standard Connections Drawing

Fitting part dimensions

 

(Unit: mm)

 

Fitting sizeVAC/SET
StraightElbowElbowElbow
RSTU
ø6 (diameter 6 mm), ø1/4" (diameter 1/4" mm)1019263
ø8 (diameter 8mm), ø5/16" (diameter 5/16" mm)1220286
IRV10-□□□Z (N/P/A/B): drawing with digital pressure switch

IRV10-□□□Z (N/P/A/B): drawing with digital pressure switch

Fitting part dimensions

 

(Unit: mm)

 

Fitting sizeVAC/SET
StraightElbowElbowElbow
RSTU
ø6 (diameter 6 mm), ø1/4" (diameter 1/4" mm)1019263
ø8 (diameter 8mm), ø5/16" (diameter 5/16" mm)1220286

Drawing of IRV10A: Single-Sided Connections

 

(Unit: mm)

 

IRV10A-□□□G: drawing with pressure gauge

IRV10A-□□□G: drawing with pressure gauge

Fitting part dimensions

 

(Unit: mm)

 

Fitting sizeVAC/SET
StraightElbowElbowElbowElbow
RSTUV
ø6 (diameter 6 mm), ø1/4" (diameter 1/4" mm)1019267.511
ø8 (diameter 8mm), ø5/16" (diameter 5/16" mm)12202810.514

 

(Unit: mm)

 

IRV10A-□□□Z (N/P/A/B): drawing with digital pressure switch

IRV10A-□□□Z (N/P/A/B): drawing with digital pressure switch

Fitting part dimensions

 

(Unit: mm)

 

Fitting sizeVAC/SET
StraightElbowElbowElbowElbow
RSTUV
ø6 (diameter 6 mm), ø1/4" (diameter 1/4" mm)1019267.511
ø8 (diameter 8mm), ø5/16" (diameter 5/16" mm)12202810.514

*Please refer to the manufacturer's catalog for other models and specifications.

Teilenummer
IRV10-N09BG
IRV10-N09G
IRV10-N09ZN
IRV10A-N09BG
IRV20-N09
IRV20-N09B
IRV20-N09BG
IRV20-N09LG
Teilenummer
Standard-Stückpreis
MindestbestellmengeMengenrabatt
Reguläre
Versanddauer
?
Geeignetes Fluid
(L/min)
Versorgungsseite, Verbindungsausführung Versorgungsseite, Rohrleitungsgewinde, Nenn-Ø Versorgungsseite, Verbindungsrohr-Ø Steuerseite, Verbindungsausführung Steuerseite, Rohrleitungsgewinde, Nenn-Ø Steuerseite, Verbindungsrohr-Ø Festgelegter Druckbereich
(kPa)
Spezifikationen Anschluss Zubehör Kundenspezifische Vorgaben Versorgungsseitige Anschlussform Steuerseitige Anschlussform Befestigungselement

120.10 €

1 26 Arbeitstage 140One-Touch-Installation-Ø5 / 16"One-Touch-Installation-Ø5 / 16"-100~-1.3StandardanschlüsseManometer (GZ33-K-01)NeinGeradeGeradeMit Befestigungselement

117.15 €

1 26 Arbeitstage 140One-Touch-Installation-Ø5 / 16"One-Touch-Installation-Ø5 / 16"-100~-1.3StandardanschlüsseManometer (GZ33-K-01)NeinGeradeGeradeNein

193.00 €

1 26 Arbeitstage 140One-Touch-Installation-Ø5 / 16"One-Touch-Installation-Ø5 / 16"-100~-1.3StandardanschlüsseDigitaler Druckabschaltung (NPN Open Collector 1 Ausgang)NeinGeradeGeradeNein

125.87 €

1 26 Arbeitstage 140One-Touch-Installation-Ø5 / 16"One-Touch-Installation-Ø5 / 16"-100~-1.3Anschluss einseitig SpezifikationManometer (GZ33-K-01)NeinGeradeGeradeMit Befestigungselement

99.85 €

1 26 Arbeitstage 240One-Touch-Installation-Ø5 / 16"One-Touch-Installation-Ø5 / 16"-100~-1.3StandardanschlüsseNeinNeinGeradeGeradeNein

102.81 €

1 26 Arbeitstage 240One-Touch-Installation-Ø5 / 16"One-Touch-Installation-Ø5 / 16"-100~-1.3StandardanschlüsseNeinNeinGeradeGeradeMit Befestigungselement

123.92 €

1 26 Arbeitstage 240One-Touch-Installation-Ø5 / 16"One-Touch-Installation-Ø5 / 16"-100~-1.3StandardanschlüsseManometer (GZ43-K-01)NeinGeradeGeradeMit Befestigungselement

125.82 €

1 26 Arbeitstage 240One-Touch-Installation-Ø5 / 16"One-Touch-Installation-Ø5 / 16"-100~-1.3StandardanschlüsseManometer (GZ43-K-01)NeinGeradeGeradeMit Tretlager

Loading...

  1. 1

Grundlegende Informationen

Modell Vakuumregler Steuermethode Linearbewegungsmodell Form Standard

Technischer Support