Teilenummer
Hier finden Sie die Teilenummern
zu dem gesuchten Artikel
Teilenummer
|
---|
810-191-21 |
810-193-31 |
810-194-31 |
Teilenummer | Bezieht sich auf |
Standard-Stückpreis
| Mindestbestellmenge | Mengenrabatt | Ca. Masse Hauptgerät (kg) | Datenausgabe | Beschreibung | Anzeigeeinheit | Funktionen | Bruttogewicht (g) | HR Auflösung | Modell | Nettogewicht (g) | Prüfvorkraft (N) | Einstellung Prüfvorkraft | Auflösung | Super-Rockwellskala Kugel 1,5875 mm | Super-Rockwellskala Kugel 12,7mm | Super-Rockwellskala Kugel 3,175 mm | Super-Rockwellskala Kugel 6,35 mm | Super-Rockwellskala Diamant | Normen | Standardzubehör | Prüfkraft Verweilzeit | Prüfkrafteinstellung | Prüfkraft Super-Rockwell (N) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
5,494.74 € | 1 | 5 Arbeitstage | 47 | - | The HR-210MR is an economical Rockwell hardness testing machine to suit practically every application you need. The MR indicates the Rockwell testforce range.It offers you the following benefits:The frame was designed with great care to provide maximum clearance for positioning the work piece. All you need is a flat table for mounting these testing machines.Its outstanding robustness makes it perfect for even the roughest environments.You can attach the clamping device K543817 to for safe operation with hard to handle workpieces.The analogue type HR-210MR uses an automatic presetting dial gauge which makes it easy to operate.You can perform Brinell hardness tests, as indicated, by using the following optional accessories:a Brinell indenter and a measurement microscope. | Analogue dial indicator | To observe the hardness number within 0,2 HR of the scale unit, as required by ISO 6508-2, the displayed result is to be judged by the dial hand width within the step of the dial gage scale. | 69.000 | 0,5 HR | HR-210MR | 45.600 | 98,07 | - | 0,5 HR graduation | - | - | - | - | - | JIS B 7726, ISO 6508-2 | 810-039 Flat anvil Ø64mm 810-040 V-anvil outside diameter Ø40mm groove width 30mm11AAB941 Water level383876 Vinyl cover357651 AC adaptorIndenters, reference materials and power cord not included | Festgelegt auf 3-5,5 Sek. oder manuell | Manual weight exchange | - | |||
9,390.79 € | 1 | 60 Arbeitstage | 49,3 | Digimatic (SPC), RS-232C | The HR-430MR is an economical Rockwell hardness testing machine to suit practically every application you need. The MR indicates the Rockwell testforce range.It offers you the following benefits:The frame was designed with great care to provide maximum clearance for positioning the work piece. All you need is a flat table for mounting these testing machines.Its outstanding robustness makes it perfect for even the roughest environments.The HR-430MR is very simple to operate. It uses automatic steering wheel braking and load sequencing for easy handling.You can attach the clamping device K543817 to for safe operation with hard to handle workpieces.This digital model can use our Digimatic Mini-processor (DP-1VR) for printing results, and you can use an input tool (USB-ITN-E) to connect to a PC for data transfer, analysis and storage.You can perform Brinell hardness tests, as indicated, by using the following optional accessories:a Brinell indenter and a measurement microscope. | Matrix backlight LCD | GO/NG, Hardness value offset, Hardness conversion, Data output, Calibration mode | 70.000 | 0,1 HR | HR-430MR | 49.300 | 98,07 | - | 0,1 HR indication | - | - | - | - | - | JIS B 7726; ISO6508-2; ASTM E18 | 810-39 Flat anvil Ø64mm 810-40 V-anvil outside diameter Ø40mm groove width 30mm11AAB941 Water level383876 Vinyl cover357651 AC adaptorIndenters, reference materials and power cord not included | Settable 1-99s. | Dial switching | - | |||
10,646.05 € | 1 | 5 Arbeitstage | 49,9 | Digimatic (SPC), RS-232C | The HR-430MS is an economical Rockwell hardness testing machine to suit practically every application you need. The MS indicates the Rockwell and Rockwell Superficial testforce range. It offers you the following benefits:The frame was designed with great care to provide maximum clearance for positioning the work piece. All you need is a flat table for mounting these testing machines.Its outstanding robustness makes it perfect for even the roughest environments.The HR-430MS is very simple to operate. It uses automatic steering wheel braking and load sequencing for easy handling.This digital model can use our Digimatic Mini-processor (DP-1VR) for printing results, and you can use an input tool (USB-ITN-E) to connect to a PC for data transfer, analysis and storage.You can perform Brinell hardness tests, as indicated, by using the following optional accessories: a Brinell indenter and a measurement microscope. | Matrix backlight LCD | GO/NG, Hardness value offset, Hardness conversion, Data output, Calibration mode | 72.000 | 0,1 HR | HR-430MS | 49.900 | 29,42; 98,07 | Dial switching | 0,1 HR indication | HR15TW, HR30TW; HR45TW | HR15YW, HR30YW; HR45YW | HR15WW, HR30WW; HR45WW | HR15XW, HR30XW; HR45XW | HR15N; HR30N; HR45N | JIS B 7726; ISO6508-2; ASTM E18 | 810-39 Flat anvil Ø64mm 810-40 V-anvil outside diameter Ø40mm groove width 30mm11AAB941 Water level383876 Vinyl cover357651 AC adaptorIndenters, reference materials and power cord not included | Settable 1-99s. | Dial switching | 147,1; 294,2; 441,3 |
Loading...
Product Type | Härteprüfung | Amboss Adaptierung(mm) | Ø 19 | Brinellskala Kugel 1,0 mm | HBW 1/10; HBW 1/30 - nur Eindruck (nicht normgerecht durch Anwendung der Prüfvorkraft) |
---|---|---|---|---|---|
Brinellskala Kugel 10,0 mm | HBW 10/100 - nur Eindruck (nicht normgerecht durch Anwendung der Prüfvorkraft) | Höhe(mm) | Max. 180 mm | Jominytest Fähigkeit* | Optionales Zubehör erforderlich |
Abmaße Hauptgerät(mm) | 214x512x780 | Max. Probenhöhe(mm) | 180 | Max. Probenmasse(kg) | 20 |
Messtiefe(mm) | Max. 165 mm (von der Mitte der Indenteraufname) | Rockwellskala Kugel 1,5875 mm | HRFW; HRBW; HRGW | Rockwellskala Kugel 12,7 mm | HRRW; HRSW; HRVW |
Rockwellskala Kugel 3,175 mm | HRHW; HREW; HRKW | Rockwellskala Kugel 6,35 mm | HRLW; HRMW; HRPW | Rockwellskala Diamant | HRA; HRD; HRC |
Prüfkraftkontrolle | Halbautomatisch | Prüfkraft Rockwell(N) | 588,4; 980,7; 1471 | Ausladung(mm) | 165 |
Konfigurieren
Basiseigenschaften
Ca. Masse Hauptgerät(kg)
Datenausgabe
Beschreibung
Anzeigeeinheit
Funktionen
Bruttogewicht(g)
HR Auflösung
Modell
Nettogewicht(g)
Prüfvorkraft(N)
Einstellung Prüfvorkraft
Auflösung
Super-Rockwellskala Kugel 1,5875 mm
Super-Rockwellskala Kugel 12,7mm
Super-Rockwellskala Kugel 3,175 mm
Super-Rockwellskala Kugel 6,35 mm
Super-Rockwellskala Diamant
Normen
Standardzubehör
Prüfkraft Verweilzeit
Prüfkrafteinstellung
Prüfkraft Super-Rockwell(N)
Ausführung
Filtern nach vsl. Lieferzeit
Optionale Eigenschaften